[Sony Service]

                             Technical Services

                       Electronic Service Information

                           Field Problem Reports

  ------------------------------------------------------------------------
                             FPR Number: P1246
                         Submitted by: JIM GRIGNON
                                Engineer: LD
Model(s):
STRD311

Subject:     NO AUDIO OUTPUT - D955 SHORTED
Symptom:     151
Last Update: 2000-11-14
Status:      Closed

Customer Description:
No audio. No -12v.
Solution:
D955 is in circuit to regulate -24 to -12. -12 is used throughout the
unit. D955 shorted.
Technical Description:

Part's Information:
 P/N          Description                    Reference   Board   Symptom

 871901074    G10/ZENER DIODE(UZ-12SB)       D955        MAIN